Fire-protection cladding set in concrete

  • Wall apron fixed with nail anchors

    Fire-protection cladding set in concrete - permanent formwork

    1. Fixing of wall apron
    Fixings: Nail anchors with washers

    2. Backing strips (wall fixing)
    AESTUVER T fire-protection board
    Width: 50 mm – Thickness: 10 mm
    Fixings: Staples

    3. Wall apron
    AESTUVER Tx fire-protection board

    4. Backing strips (transverse and longitudinal joints)
    AESTUVER T fire-protection board
    Width: 100 mm – Thickness: 10 mm
    Fixings: Staples

    5. Joints – Closely butted

    6. Ceiling cladding set in concrete
    AESTUVER T fire-protection board

  • Wall apron set in concrete

    Wall apron set in concrete

    1. Wall apron set in concrete
    AESTUVER T fire-protection board

    2. Composite support
    AESTUVER screws

    3. Backing strips (wall fixing)
    AESTUVER T fire-protection board
    Width: 50 mm – Thickness: 10 mm
    Fixings: Staples

    4. Backing strips (transverse and
    longitudinal joints)
    AESTUVER T fire-protection board
    Width: 100 mm – Thickness: 10 mm
    Fixings: Staples

    5. Joints – Closely butted

    6. Ceiling cladding set in concrete
    AESTUVER T fire-protection board

  • Backing strips

    Backing strips

    1. Ceiling cladding set in concrete
    AESTUVER T fire-protection board

    2. Fixing of backing strips
    Fixings: Staples

    3. Joints – Closely butted

    4. Backing strips (transverse and longitudinal joints)
    AESTUVER T fire-protection board
    Width: 100 mm – Thickness: 10 mm
    Fixings: Staples

  • Fire-protection cladding set in concrete in the haunch region

    With AESTUVER joint tape

    With AESTUVER joint tape

    1. Wall apron
    AESTUVER Tx fire-protection board

    2. Joints
    AESTUVER T joint tape 1330

    3. Backing strips (wall fixing)
    AESTUVER T fire-protection board
    Width: 50 mm – Thickness: 10 mm
    Fixings: Staples

    4. Ceiling cladding set in concrete
    AESTUVER T fire-protection board

    5. Backing strips (transverse and longitudinal joints)
    AESTUVER T fire-protection board
    Width: 50 mm – Thickness: 10 mm
    Fixings: Staples

    6. Board joint – Closely butted

    Without AESTUVER joint tape

    Without AESTUVER joint tape

    1. Wall apron
    AESTUVER Tx fire-protection board

    2. Joints – Closely butted

    3. Backing strips (wall fixing)
    AESTUVER T fire-protection board
    Width: 50 mm – Thickness: 10 mm
    Fixings: Staples

    4. Ceiling cladding set in concrete
    AESTUVER T fire-protection board

    5. Backing strips (transverse and longitudinal joints)
    AESTUVER T fire-protection board
    Width: 50 mm – Thickness: 10 mm
    Fixings: Staples

    6. Board joint – Closely butted