Independently fitted fire-protection cladding

  • Independently fitted ceiling cladding (with backing strips)

    Fixings: Nail anchors

    Independently fitted ceiling cladding (with backing strips)

    1. Wall apron
    AESTUVER Tx fire-protection board

    2. Fixing of wall apron
    Fixings: Nail anchors with washers

    3. Independently fitted ceiling cladding
    AESTUVER Tx fire-protection board

    4. Fixing of fire-protection cladding
    Fixings: Nail anchors with washers

    5. Joints – Closely butted

    6. Backing strips (transverse and longitudinal joints)
    AESTUVER T fire-protection board
    Width: 100 mm – Thickness: 10 mm

    Fixings: Concrete screws

    Independently fitted ceiling cladding (with backing strips)

    1. Wall apron
    AESTUVER Tx fire-protection board

    2. Fixing of wall apron
    Fixings: Concrete screws with washers

    3. Independently fitted ceiling cladding
    AESTUVER Tx fire-protection board

    4. Fixing of fire-protection cladding
    Fixings: Concrete screws with washers

    5. Joints – Closely butted
    6. Backing strips (transverse and longitudinal joints)

    AESTUVER T fire-protection board
    Width: 100 mm – Thickness: 10 mm

  • Independently fitted ceiling cladding (without backing strips)

    Fixings: Nail anchors

    Independently fitted ceiling cladding (without backing strips)

    1. Wall apron
    AESTUVER Tx fire-protection board

    2. Fixing of wall apron
    Fixings: Nail anchors with washers

    3. Independently fitted ceiling cladding
    AESTUVER Tx fire-protection board
    Format: 1 300 × 625 mm

    4. Fixing of fire-protection cladding
    Fixings: Nail anchors with washers

    5. Joints – Closely butted

  • Independently fitted ceiling cladding (on metal substructure)

    Independently fitted ceiling cladding (on metal substructure)

    1. Wall apron
    AESTUVER Tx fire-protection board

    2. Fixing of wall apron
    Fixings: Nail anchors with washers

    3. Independently fitted ceiling cladding on substructure
    AESTUVER Tx fire-protection board

    4. Fixing of fire-protection cladding
    Fixings: Screws with drill points and washers

    5. Metal substructure

    6. Fixing of metal substructure
    Fixings: Nail anchors with washers

    7. Joints – Closely butted

    8. Backing strips (transverse and longitudinal joints)
    AESTUVER T fire-protection board
    Width: 100 mm – Thickness: 10 mm

    Independently fitted ceiling cladding (on metal substructure)

    1. Independently fitted ceiling cladding on substructure
    AESTUVER Tx fire-protection board

    2. Backing strips (transverse and longitudinal joints)
    AESTUVER T fire-protection board
    Width: 100 mm – Thickness: 10 mm

    3. Fixing of backing strips (transverse joints)
    Fixings: Staples
    4. Fixing of fire-protection cladding
    Fixings: Screws with drill points and washers

    5. Fixing of metal substructure
    Fixings: Nail anchors with washers

    Independently fitted ceiling cladding (on metal substructure)

    1. Independently fitted ceiling cladding on substructure
    AESTUVER Tx fire-protection board

    2. Backing strips (transverse and longitudinal joints)
    AESTUVER T fire-protection board
    Width: 100 mm – Thickness: 10 mm

    3. Fixing of backing strips (transverse and longitudinal joints)
    Fixings: Staples

    4. Fixing of metal substructure
    Fixings: Nail anchors with washers

    5. Fixing of fire-protection cladding
    Drilltip: Screws and washers

    6. Joints – Closely butted
    7. Metal substructure

  • Fixing elements for tunnel technology

    Fixing elements for tunnel technology

    1. Double-layer board
    AESTUVER Tx fire-protection board

    2. Fixing of double-layer board
    Fixings: Drywall screws

    3. Joints
    AESTUVER DSB joint tape

    4. Fixing elements for tunnel technology

    5. Subsequently fixed ceiling cladding
    AESTUVER Tx fire-protection board

  • Penetration of fire-protection board for tunnel technology

    Penetration of fire-protection board for tunnel technology

    1. Backing strips
    AESTUVER T fire-protection board

    2. Fixing of fire-protection cladding
    Fixings: Concrete screws with washers

    3. Subsequently fixed ceiling cladding
    AESTUVER Tx fire-protection board

    4. Stainless-steel sleeve

    5. Joints – Closely butted

  • Joint tolerance

    Joint tolerance

    1. Joint tolerance
    Maximum: 2 mm

  • Height tolerance

    Height tolerance

    1. Height tolerance
    Maximum: 3 mm